150 kW generators, used and ready to buy.
A used diesel built at exactly 150 kW, plus every gas and diesel set from 120 to 180 kW that is listed for sale. Each one is quoted on its own hours and condition, from the Red Deer yard.
A John Deere diesel with its own tank.
This set pairs a John Deere 4045 engine with a Stamford generator end wired for 277/480 V. It lives in a sound-attenuated trailer enclosure that also carries a 500-gallon double-wall fuel tank, so the set and its fuel move as one piece rather than as a generator and a separate tank.
It is listed for sale, and for rent as well, in used, good condition. The listing describes the hours as low. Ask for the meter reading and the service record with the quote; the used generators page explains what to look for in both.
| Engine | John Deere 4045 diesel |
|---|---|
| Hours | Low |
| Output | 150 kW |
| Voltage | 277/480 V |
| Alternator | Stamford generator end |
| Enclosure | Sound-attenuated trailer |
| Fuel Tank | 500 gal double-wall |
| Condition | Used — good condition |

Every set near 150 kW you can buy today.
Gas and diesel side by side, smallest first, read from inventory every hour. A 150 kW load with easy motor starts may sit comfortably on the smaller sets; a hard start pushes toward the larger ones. The gas units need a line or a propane supply on site.

NPI Series 125
125 kW- Output
- 156 kVA
- Frequency
- 60 Hz
- Voltage
- 480V
- Fuel
- NG / LP

CAT XQ135
135 kW- Frequency
- 60 Hz
- Voltage
- 480 V / 600 V
- Fuel
- Natural Gas

150 kW Diesel
150 kW- Frequency
- 60 Hz
- Voltage
- 277/480 V
- Fuel
- Diesel

MAN E2876E312
155 kW- Frequency
- On request
- Voltage
- 480 V
- Fuel
- Natural Gas

NPI Series 170
170 kW- Frequency
- 60 Hz
- Voltage
- 480 V
- Fuel
- NG / LP
Only need it for a while? Airman SDG220 is in this range but listed for rent only. The 100 kW rental page covers the class below, the 200 kW natural gas page the class above, and the generators by size table lists everything in the fleet.
What 150 kW works out to.
Used sets are often advertised in kVA, and an ad for a "150 kVA" generator describes a 120 kW machine. The table gives the 150 kW figures in kVA and in the current each phase carries, which is what the cable and breaker are sized from.
Before buying, compare the set's voltage with the building or site. A 277/480 V set on a 347/600 V service needs a transformer, and that belongs in the budget. The power calculators convert any other rating.
| 150 kW load | Figure |
|---|---|
| Output | 150 kW |
| Apparent power at 0.8 pf | 187.5 kVA |
| Amps per phase, 208 V | about 520 A |
| Amps per phase, 480 V | about 226 A |
| Amps per phase, 600 V | about 180 A |
The fuel on site picks the set.
At 150 kW both fuels are common, and the choice usually comes down to what the site already has and how many hours a year the set will run.
Diesel
Fuel arrives by truck, so the set works anywhere a tank can be filled: a remote lease, a construction lot, a yard with no gas service. A tank on the set or beside it decides how long it runs between fills.
Diesel generators for sale →Natural gas or propane
On a gas line the fuel never needs ordering, which is why gas suits a set that will run every day or stand by for long outages. The line has to deliver the full-load volume at the pressure the engine wants.
Natural gas generators for sale →Buying for standby? The standby generators page covers transfer switches and what has to come back after an outage. Weighing a purchase against renting, see renting vs. buying.
150 kW generator questions.
What does a used 150 kW generator cost?
Each unit is priced on its own. Hours, overhaul history, condition, voltage, enclosure and anything that comes with it, such as a trailer or fuel tank, all move the figure, so no list price is published. Name the unit and the quote comes back in writing.
Is a 150 kW generator the same as a 150 kVA generator?
No. At the 0.8 power factor three-phase sets are rated at, 150 kVA is 120 kW, a size smaller. A 150 kW set is 187.5 kVA. When comparing listings or quotes, check which unit each figure uses.
What will a 150 kW generator run?
A small shop or plant, a lease with a few pump motors and heat trace, a camp kitchen and dorms, or standby for a commercial building's essential circuits. The deciding number is often the largest motor and how it starts, not the total load. Send the motor list and the desk will size it.
Can a 480 V generator feed a 600 V building?
Not on its own; it needs a step-up transformer, which can be quoted with the set. Some sets in this size range list 600 V on their card, such as the CAT XQ135, and avoid the transformer.
Can I rent a 150 kW generator before buying one?
Several units here are listed for rent as well as sale, and some are flagged Rent to Own, where rental payments go toward the purchase. Ask for both prices on the same quote.
How does a 150 kW generator get to my site?
Units leave from the NexSource yard at 77 Queensgate Cres, Red Deer, and transport is part of the written quote. A set on its own trailer is the simplest to move.
Shopping for 150 kW? Name the unit.
Or send the load, voltage and fuel and the desk will point to the right set. Every unit ships from Red Deer to sites across Alberta and Saskatchewan, and field service answers 24/7.

