500 kW generator rental, in one container.
Half a megawatt covers a large building, a plant shutdown or a busy construction site. This page covers the 500 kW CAT set in the rental fleet, the gas options near this size, and the fuel, cable and connection that come with a load this large. Supplied from Red Deer across Alberta.
The CAT XQ570, a 500 kW diesel.
A Caterpillar rental package built into a container, with the controls, fuel tank and generator inside the one box. Its listing gives 500 kW at 60 Hz and an output range of 120 to 600 V. It is listed for rent.
The EMCP 4.4 panel does the metering and protection. The same controller handles automatic paralleling, so a second compatible set can be added if the load grows, or two smaller sets can share it.
- CAT EMCP 4.4 digital control panel — power metering, protection and monitoring
- Automatic paralleling for up to eight generator sets
- CAT Connect remote monitoring for fleet management
- 24-hour double-wall integral fuel tank
| Output | 500 kW |
|---|---|
| Voltage | 120–600V |
| Frequency | 60 Hz |
| Fuel | Diesel |
| Controls | CAT EMCP 4.4 |

500 kW is 625 kVA.
Sets this size are quoted in either unit, and mixing them up costs a size class. A "500 kVA" set delivers 400 kW. The 500 kW set here is a 625 kVA machine.
The voltage decides how hard the cable has to work. At 600 V the current stays near 600 A; at 208 V it is close to three times that, which is why a load this size is rarely fed at 208 V without a transformer near the load. The amperage table covers other ratings.
| A 500 kW load | Works out to |
|---|---|
| Real power | 500 kW |
| Apparent power at 0.8 pf | 625 kVA |
| Current at 208 V | about 1,735 A per phase |
| Current at 480 V | about 752 A per phase |
| Current at 600 V | about 601 A per phase |
Diesel and gas near 500 kW.
Read from the inventory every hour, so a set going out on a job drops off this list. Where there is a gas supply on site, the gas set saves the fuel deliveries; where there is not, the diesel is the simpler job.

CAT DG400
400 kW- Frequency
- 60 Hz
- Voltage
- 208–600V, 3-Phase
- Fuel
- NG / LP

CAT XQ570
500 kW- Frequency
- 60 Hz
- Voltage
- 120–600V
- Fuel
- Diesel
500 kW on gas from two sets. NexSource builds the NPI Series in Red Deer as parallel-ready natural gas and propane packages, and two NPI250s together come to 500 kW. Whether a pair is free for your dates is confirmed on the quote, like any set.
Smaller or larger. Loads nearer 350 kW are on 350 kW generator rental, and a megawatt and up on 1 MW generator rental. The generators by size table lists every set in kW order.
At 500 kW, the set is half the job.
The other half is getting fuel in and power out. These four are planned with the set.
Fuel
The XQ570's listing gives it a 24-hour double-wall tank. How long that lasts depends on the load, so a job of more than a day or two plans fills, or an external tank, from the start.
Fuel tank rentals →Cable
At 480 V the set supplies about 750 A per phase, more than one run of cable carries. Parallel runs and a distribution panel sized for it are part of the quote, not an afterthought.
Power distribution rentals →Connection
Into the building's transfer switch, straight onto the main, or out to temporary panels. Who makes the connection, and where, is agreed before the set leaves the yard.
Transfer switch rentals →Placement
A container on a trailer needs a truck route in, level ground and room around it for air and service. Send a photo or a site plan with the request.
Construction generator rental →A set this size that runs lightly for weeks does not burn clean, so a load bank sometimes goes out with it. The fuel consumption calculator gives a burn rate to plan fills around.
What to send with a 500 kW request.
The 500 kW figure
Logged peak, utility demand, or a sum of nameplates. A sum of nameplates usually overstates it.
The largest motor starts
Horsepower, starting method, and whether any start together after an outage.
Voltage and phase
480 V, 600 V or 120/208 V, three-phase, and where the connection is made.
Fuel
Diesel with fills, or a gas supply with its pressure and an analysis if it is not utility gas.
Term and hours
Days, weeks or months, and whether it runs around the clock or covers outages.
Site and access
Location, the route in for a truck and trailer, and the ground it will sit on.
Questions at 500 kW.
How many amps does a 500 kW generator supply?
At 0.8 power factor a 500 kW three-phase load is 625 kVA. That is about 752 A per phase at 480 V, 601 A at 600 V, and roughly 1,735 A at 208 V. The amperage table on the tools page does the same sum for other ratings.
Is a 500 kVA generator the same as 500 kW?
No. At 0.8 power factor a 500 kVA set delivers 400 kW, a full size class down. If a specification or an older quote gives a figure without the unit, find out which it means before comparing sets.
Do you rent a generator rated at 500 kW?
Yes. The CAT XQ570 is listed at 500 kW and is listed for rent; its card is on this page. A listing is not a booking, so the desk confirms it is free on your dates with the quote.
Is the 500 kW a prime or a standby rating?
The listing gives 500 kW without saying which, and the difference matters for a set that will run all day. Tell us how the load runs and for how long, and the quote states the rating the set is supplied at.
How long does a 500 kW generator run on one tank?
The XQ570's tank is listed as a 24-hour tank, but the real figure depends on how hard the set is working. The fuel consumption calculator gives a rate at your load, and a long job adds an external tank or scheduled fills.
What does a 500 kW generator rental cost?
There is no rate card. The quote covers the set, the term, fuel or fuel supply, transport from Red Deer, and the cable, distribution and transfer equipment the job needs, in writing.
Planning around 500 kW? Send the load.