Skip to content
NPI — NexSource Power Inc.

When the generator is the power plant

Prime power natural gas generators.

Gas generators that run a site with no grid behind them, day and night, for months or for years.

The NPI Series is built in Red Deer for this work, and gas sets from other makers are on offer from stock. Each can be bought or rented, set up for the gas on site and run in parallel as the load grows.

NPI generator enclosures set up together beside production tanks on a gravel lease
NPI generator packages working side by side on a producing lease.

Why gas for prime power

The longer the run, the stronger the case for gas.

01

The fuel comes by pipe

A set on a gas line or on gas from the lease is never waiting for a fuel truck. On a job that runs for a season or for years, that removes the deliveries, the storage tank and the risk of a road closing in February.

02

Nothing to go stale

Pipeline gas does not age in a tank, gel in the cold or pick up water the way stored diesel can. The fuel the engine burns in month twelve is the same as in week one.

03

Built for the hours

A prime set runs most hours of the year, so the engine choice matters more than the purchase price. Gas engines built for continuous industrial work are designed around that kind of duty.

What a prime rating means, and how it differs from standby and continuous, is on prime power generator rentals. Where no gas is available, diesel generators bring their own fuel.

What the site has to provide

Five things a gas engine needs from a prime site.

A gas generator on prime duty is only as good as the gas and the load it is given. These are the points to settle before a set is chosen, not after it arrives.

Gas that keeps up at full load

The supply has to hold its pressure while the set is working hardest, all day, on top of whatever else is on the same line. Ask the utility or the lease operator for the pressure and the volume available before choosing a set.

Gas the engine can burn

Line gas is consistent. Lease and casing gas can carry liquids, hydrogen sulphide or heavy hydrocarbons that shorten an engine's life. A current gas analysis decides whether the gas can be used and what scrubbing and regulation go in front of the engine.

Load added in steps

A spark-ignited gas engine takes on a sudden block of load less readily than a diesel. On a prime site, big motors are started one at a time, often on soft starters or drives, so the set never has to pick up everything at once.

An engine kept busy

An engine that idles along at a fraction of its rating for months wears in ways a working engine does not. Size the set close to the real load, or split the load across smaller sets that each run well-loaded.

Allowance for altitude and heat

A gas engine's output falls as the air thins and warms. A set rated at sea level may not make its nameplate figure on a hot day in the foothills, so the figure that counts is the derated one for your site.

Burning lease or casing gas is covered in more depth on industrial natural gas generator rentals, and the fuel consumption calculator gives a first figure to take to the gas supplier.

Built for it

The NPI Series on prime duty.

NexSource designs and builds the NPI Series in its Red Deer shop as natural gas and propane packages for sites that run on their own power: producing leases, remote facilities, plants beyond the reach of a line.

The NPI250 and NPI350 have controllers that can parallel. That lets a site grow in steps instead of buying for a load it may never reach, and it lets one unit come off for servicing while the others carry the site.

Planned maintenance on NPI units includes oil sampling, so each change adds to a record of how the engine is wearing on that site's gas.

See the NPI Series

How NPI250 and NPI350 units add up when run in parallel
Sets in parallelNPI250NPI350
One set250 kW350 kW
Two sets500 kW700 kW
Three sets750 kW1,050 kW

Nameplate figures added together. Running a site at less than the total, so one set can be taken out of service, is usually the better plan.

Gas sets on offer

Natural gas generators from 50 kW up.

Every gas and dual-fuel set listed to rent or buy, refreshed from the inventory each hour. A set is marked as paralleling only when its own listing says so; the rating it carries on your site is confirmed in the quote.

UnitOutputVoltageParallelsOffered
NPI NG50 · 50 kW Natural Gas / Propane Generator50 kW480 VNot statedRent or buy
70 kW Cummins Natural Gas Generator70 kW480 VNot statedRent or buy
125 kW Natural Gas Generator125 kW480VNot statedRent or buy
XQ135 kW Portable Natural Gas Generator135 kW480 V / 600 VListed as parallel-capableRent or buy
MAN 155 kW Generator Package155 kW480 VListed as parallel-capableBuy
NPI Series 170 · 170 kW Natural Gas / Propane Generator170 kW480 VNot statedRent or buy
200 kW · 600 V Natural Gas Generator200 kW347/600 VNot statedRent or buy
NPI250 · 14L · 250 kW Generator Set250 kW480 VListed as parallel-capableRent or buy
NPI-350 · 350 kW Natural Gas / Propane Generator350 kW480 VListed as parallel-capableRent or buy
Caterpillar 375 kW Natural Gas / Propane Generator375 kW600 V, 3 phaseNot statedRent or buy
400 kW Natural Gas Generator400 kW208–600V, 3-PhaseNot statedRent
Caterpillar XQ1250G Natural Gas Generator Set1,250 kW480 VListed as parallel-capableRent or buy
Used XQ1475 kW Natural Gas Generator1,475 kW480 VNot statedRent or buy
1900 kW Natural Gas / Propane Generator1,900 kWOn requestNot statedRent or buy

By size, see the 70 kW, 200 kW and 250 kW gas pages or generators by size. Past a megawatt, see megawatt power.

Buy or rent

It comes down to how long the site will need it.

Buy

For a facility that will run on its own power for years: no utility line coming, or one too costly to bring in. Ownership puts the set on the site's books, and the service plan is set up when it is commissioned.

Natural gas generators for sale

Rent

For a site waiting on a tie-in, a well still being proven, or a load that may change. Servicing is arranged with the rental, and sets can be added or swapped as the load becomes clear.

Prime power generator rentals

NexSource works from one shop, at 77 Queensgate Crescent in Red Deer. Sets for prime sites across Alberta and Saskatchewan are prepared and serviced from there, and the field service line, (403) 887-4567, is answered 24 hours a day. See generator service.

Prime gas questions

Before you run a site on gas.

What is a prime power natural gas generator?

A gas-fuelled generator rated to be a site's only source of power, running for unlimited hours at a load that varies through the day. It is chosen against its prime rating, which is lower than the standby figure on the same nameplate.

How long can a natural gas generator run without stopping?

As long as the gas supply holds and the servicing keeps pace. A prime set is built to run around the clock; what eventually stops it is an oil change or a scheduled inspection, which is why a second set, or one unit spare among several, is planned for sites that cannot go down.

Can it run on gas from our own lease?

Often, but not on trust. Send a recent gas analysis along with the pressure and the volume available. That decides whether the gas suits the engine and what has to treat it first.

Natural gas or diesel for prime power?

Gas where it is available and the load can be started in steps. Diesel where there is no gas, or where very large loads have to come on all at once.

Can we start with one set and add more later?

Yes, if the sets are built to parallel. The NPI250 and NPI350 carry parallel-capable controllers, so a second or third unit can join the first on the same bus. On other sets, check the Parallels column above or the listing itself.

Should we buy or rent a prime gas generator?

Buy when the site will need its own power for years: a facility with no prospect of a utility connection, or one where the connection is uneconomic. Rent when the end date is known or uncertain, such as waiting for a tie-in or testing a well. Many listings can be quoted both ways for comparison.

What does a prime power natural gas generator cost?

There are no published prices. The set, purchase or rental term, the gas train, any transformer and switchgear, transport from Red Deer and the service plan are all itemised in the quote.

Send the load, the gas and the term.

With a gas analysis or the utility's pressure figure, that is enough to name the sets, how they would share the load and whether to buy or rent.