A 70 kW gas genset, ready to rent or buy.
Seventy kilowatts is the size for a single well, a shop or a pump station: too much for a portable, too little to justify a big industrial set. This page covers the Cummins gas package listed at this size, the small gas sets on either side of it, and what 70 kW comes to in kVA and amps.
A Cummins 8.3 L, load tested to 70 kW.
The engine is a six-cylinder Cummins 8.3 litre built to burn natural gas, driving a 480 V generator inside a weatherproof enclosure. It has been load tested at its full 70 kW rating, and the listing describes it as in good running condition.
It can be rented or bought, and the quote covers either. Cummins long blocks and power units are sold separately on engines for sale.
| Engine | Cummins 8.3 L (natural gas) |
|---|---|
| Output | 70 kW (load tested) |
| Voltage | 480 V |
| Control | Dynagen controller |
| Governor | Woodward L-series |
| Fuel System | Gas scrubber + regulator |
| Extras | Oil day tank w/ level control, generator breaker |
| Enclosure | Weatherproof |
| Condition | Good running, load tested |

The parts that make a small set worth owning.
A small genset is not always sold with the gas train and controls it needs to run unattended. These come fitted to this one.
Scrubber and regulator
Knock out liquids before they reach the engine and bring the line pressure down to what the carburetion expects. On a small set they are often the parts left off, and the first ones missed.
Woodward governor
Holds engine speed, and so frequency, as load steps on and off. On a 70 kW set a single motor start is a big share of the rating, so this is what decides how well it rides through one.
Dynagen controller
Starting, stopping, shutdowns and the alarm history. It is the first thing a technician reads when something has gone wrong.
Oil day tank with level control
Tops up the sump from a reserve as the engine uses oil, which stretches the time between visits on a set that runs unattended.
A generator breaker is fitted too, so the cable to the load starts from a protected point. The distribution beyond it, and any transformer, is on power distribution rentals.
70 kW comes to 87.5 kVA.
Small gensets are often sold in kVA, and the two figures are easy to mix up. At 0.8 power factor, divide kW by 0.8 to get kVA. A set advertised as "70 kVA" is a 56 kW machine, a fifth smaller than this one.
At 480 V the set supplies a little over 100 A per phase, which sizes the cable and the breaker on the load side. For other voltages or power factors, use the power calculators.
| 70 kW, three-phase | Value |
|---|---|
| Rated output | 70 kW |
| Same set in kVA (0.8 pf) | 87.5 kVA |
| Phase current at 208 V | about 243 A |
| Phase current at 480 V | about 105 A |
| Phase current at 600 V | about 84 A |
If 70 kW is not quite the right size.
A light, steady load may suit a smaller set; a load with a hard-starting motor may need the next one up. These cards are read from the inventory every hour, and each one shows whether the set can be rented, bought or both. Compare fuel and voltage before comparing anything else.

KPS-30
25 kW- Output
- 30 kVA
- Frequency
- 60 Hz
- Voltage
- 120/208 V
- Fuel
- NG / LP

NG50
50 kW- Frequency
- 60 Hz
- Voltage
- 480 V
- Fuel
- NG / LP

Cummins 70 kW
70 kW- Frequency
- 60 Hz
- Voltage
- 480 V
- Fuel
- Natural Gas

NPI Series 125
125 kW- Output
- 156 kVA
- Frequency
- 60 Hz
- Voltage
- 480V
- Fuel
- NG / LP

CAT XQ135
135 kW- Frequency
- 60 Hz
- Voltage
- 480 V / 600 V
- Fuel
- Natural Gas
Next size page up is the 100 kW generator rental, and the generators by size table lists every set in stock. Where the site has propane rather than a gas line, see propane generators.
Four jobs that usually come in around 70 kW.
A single well or small lease
A pump jack motor, heat trace, a chemical pump and the instruments, on a site that has gas but no line from the utility.
Oilfield generator rentals →A shop, office or yard
Lights, heat, a compressor and the tools, either through a long outage or before the permanent service is energized.
Power until the utility connects →A pump or lift station
One or two motors that cannot stop for long. Here the starting current, not the running load, usually sets the size.
Emergency standby generators →A few trailers on a remote site
Office and lunchroom units, lighting and heaters for a small crew, where a tie-in to a gas line saves hauling diesel all winter.
Remote camp power →If the set will run around the clock for months, read prime power natural gas generators before choosing. The fuel consumption calculator gives a first figure to put to the gas supplier.
Questions about 70 kW gas sets.
How many amps does a 70 kW generator supply?
At 480 V, about 105 A per phase. At 600 V it is about 84 A, and at 208 V about 243 A. Those figures assume a three-phase load at 0.8 power factor. The power calculators work out other voltages.
Is a 70 kW generator the same as a 70 kVA one?
No. A 70 kVA set delivers 56 kW at the usual 0.8 power factor, and a 70 kW set is an 87.5 kVA machine. When two quotes look alike, check which unit each figure is in.
Can the 70 kW set run on gas from our lease?
It comes with a fuel-gas scrubber and regulator, which is a start. Whether lease gas suits it depends on what is in the gas, so a current analysis is the first thing to send, along with the pressure at the tie-in.
Our site is 600 V or 120/208 V. Will a 480 V set work?
Yes, with a transformer between the set and the load. The transformer can be rented and quoted with the generator. For a small site that runs mostly 120/208 V equipment, the step-down transformer is usually needed anyway.
Is 70 kW big enough for our load?
Add up what runs at the same time, then look at the largest motor and how it starts. A motor started across the line can briefly draw several times its running current, which can be too much for a 70 kW set even when the running total fits. Send the motor list and the answer comes back with the quote.
What does a 70 kW natural gas generator cost?
There are no published rates. The quote covers the set, rental or purchase and the term, transport from Red Deer, and any transformer, cable or distribution the site needs.
Load around 70 kW? Send the motor list.
With the voltage and what you know about the gas, that is enough for a first answer. Sets go out from the Red Deer shop to sites in Alberta and Saskatchewan, and field service answers 24/7.