Skip to content
NPI — NexSource Power Inc.
70 kW natural gas generator

A 70 kW gas genset, ready to rent or buy.

Seventy kilowatts is the size for a single well, a shop or a pump station: too much for a portable, too little to justify a big industrial set. This page covers the Cummins gas package listed at this size, the small gas sets on either side of it, and what 70 kW comes to in kVA and amps.

Listed at 70 kW

A Cummins 8.3 L, load tested to 70 kW.

The engine is a six-cylinder Cummins 8.3 litre built to burn natural gas, driving a 480 V generator inside a weatherproof enclosure. It has been load tested at its full 70 kW rating, and the listing describes it as in good running condition.

It can be rented or bought, and the quote covers either. Cummins long blocks and power units are sold separately on engines for sale.

Cummins 70 kW figures from its inventory listing
EngineCummins 8.3 L (natural gas)
Output70 kW (load tested)
Voltage480 V
ControlDynagen controller
GovernorWoodward L-series
Fuel SystemGas scrubber + regulator
ExtrasOil day tank w/ level control, generator breaker
EnclosureWeatherproof
ConditionGood running, load tested
Cummins 8.3 litre natural gas engine with coil-on-plug ignition and the gas regulator above it, inside the 70 kW set's enclosure
The engine bay of the 70 kW Cummins set as photographed for its listing, with the gas regulator mounted above the engine and the starting batteries below.
What comes in the package

The parts that make a small set worth owning.

A small genset is not always sold with the gas train and controls it needs to run unattended. These come fitted to this one.

Scrubber and regulator

Knock out liquids before they reach the engine and bring the line pressure down to what the carburetion expects. On a small set they are often the parts left off, and the first ones missed.

Woodward governor

Holds engine speed, and so frequency, as load steps on and off. On a 70 kW set a single motor start is a big share of the rating, so this is what decides how well it rides through one.

Dynagen controller

Starting, stopping, shutdowns and the alarm history. It is the first thing a technician reads when something has gone wrong.

Oil day tank with level control

Tops up the sump from a reserve as the engine uses oil, which stretches the time between visits on a set that runs unattended.

A generator breaker is fitted too, so the cable to the load starts from a protected point. The distribution beyond it, and any transformer, is on power distribution rentals.

Reading the rating

70 kW comes to 87.5 kVA.

Small gensets are often sold in kVA, and the two figures are easy to mix up. At 0.8 power factor, divide kW by 0.8 to get kVA. A set advertised as "70 kVA" is a 56 kW machine, a fifth smaller than this one.

At 480 V the set supplies a little over 100 A per phase, which sizes the cable and the breaker on the load side. For other voltages or power factors, use the power calculators.

A 70 kW three-phase load in kVA and amps at 208, 480 and 600 V
70 kW, three-phaseValue
Rated output70 kW
Same set in kVA (0.8 pf)87.5 kVA
Phase current at 208 Vabout 243 A
Phase current at 480 Vabout 105 A
Phase current at 600 Vabout 84 A
Small gas sets, 25 to 140 kW

If 70 kW is not quite the right size.

A light, steady load may suit a smaller set; a load with a hard-starting motor may need the next one up. These cards are read from the inventory every hour, and each one shows whether the set can be rented, bought or both. Compare fuel and voltage before comparing anything else.

Next size page up is the 100 kW generator rental, and the generators by size table lists every set in stock. Where the site has propane rather than a gas line, see propane generators.

Where 70 kW gets used

Four jobs that usually come in around 70 kW.

A single well or small lease

A pump jack motor, heat trace, a chemical pump and the instruments, on a site that has gas but no line from the utility.

Oilfield generator rentals →

A shop, office or yard

Lights, heat, a compressor and the tools, either through a long outage or before the permanent service is energized.

Power until the utility connects →

A pump or lift station

One or two motors that cannot stop for long. Here the starting current, not the running load, usually sets the size.

Emergency standby generators →

A few trailers on a remote site

Office and lunchroom units, lighting and heaters for a small crew, where a tie-in to a gas line saves hauling diesel all winter.

Remote camp power →

If the set will run around the clock for months, read prime power natural gas generators before choosing. The fuel consumption calculator gives a first figure to put to the gas supplier.

Common questions

Questions about 70 kW gas sets.

How many amps does a 70 kW generator supply?

At 480 V, about 105 A per phase. At 600 V it is about 84 A, and at 208 V about 243 A. Those figures assume a three-phase load at 0.8 power factor. The power calculators work out other voltages.

Is a 70 kW generator the same as a 70 kVA one?

No. A 70 kVA set delivers 56 kW at the usual 0.8 power factor, and a 70 kW set is an 87.5 kVA machine. When two quotes look alike, check which unit each figure is in.

Can the 70 kW set run on gas from our lease?

It comes with a fuel-gas scrubber and regulator, which is a start. Whether lease gas suits it depends on what is in the gas, so a current analysis is the first thing to send, along with the pressure at the tie-in.

Our site is 600 V or 120/208 V. Will a 480 V set work?

Yes, with a transformer between the set and the load. The transformer can be rented and quoted with the generator. For a small site that runs mostly 120/208 V equipment, the step-down transformer is usually needed anyway.

Is 70 kW big enough for our load?

Add up what runs at the same time, then look at the largest motor and how it starts. A motor started across the line can briefly draw several times its running current, which can be too much for a 70 kW set even when the running total fits. Send the motor list and the answer comes back with the quote.

What does a 70 kW natural gas generator cost?

There are no published rates. The quote covers the set, rental or purchase and the term, transport from Red Deer, and any transformer, cable or distribution the site needs.

Load around 70 kW? Send the motor list.

With the voltage and what you know about the gas, that is enough for a first answer. Sets go out from the Red Deer shop to sites in Alberta and Saskatchewan, and field service answers 24/7.