Small natural gas generators, from 25 to 135 kW.
The sets for a wellsite, a shop, a pump or a handful of trailers. Here they are side by side with voltage, fuel and engine, alongside the current each size supplies and the four things that decide which one fits. Rent or buy, from the Red Deer yard.
5 small gas sets, side by side.
Read from the inventory every hour. Below about 150 kW the differences that matter are voltage and fuel more than kilowatts, so they get their own columns. Every set in the table can be bought as well as rented, unless the last column says otherwise.
| Set | Rating | Voltage | Fuel | Engine | Offered |
|---|---|---|---|---|---|
| KPS-30 · 25 kW Dual-Fuel Generator Set | 25 kW | 120/208 V | Natural Gas (NG) / Propane (LP) | Ford 2.5L | Rent or Buy |
| NPI NG50 · 50 kW Natural Gas / Propane Generator | 50 kW | 480 V | Natural Gas (NG) / Propane (LP) | Cummins 5.9L (new) | Rent or Buy |
| 70 kW Cummins Natural Gas Generator | 70 kW | 480 V | Natural Gas | Cummins 8.3 L (natural gas) | Rent or Buy |
| 125 kW Natural Gas Generator | 125 kW | 480V | Natural Gas / Propane | International 466TA, 7.6L inline-6 | Rent or Buy |
| XQ135 kW Portable Natural Gas Generator | 135 kW | 480 V / 600 V | Natural Gas | See listing | Rent or Buy |
NPI NG50 · 50 kW Natural Gas / Propane Generator and 125 kW Natural Gas Generator carry the NPI name: packaged by NexSource in Red Deer, where the NPI Series is built, and serviced by the people who built them.
Four things that pick a small gas set.
Voltage, before size
Small loads are often 120/208 V: site trailers, shop circuits, receptacles. Many small industrial sets are 480 V. A set built at the site's voltage avoids renting a transformer, so compare the voltage column before the kW column.
Line gas, lease gas or propane
A utility line at a steady pressure is the easy case. Lease gas needs an analysis and often a scrubber. Where there is no gas at all, a set listed for propane can run from a tank instead.
The biggest motor, not the total
On a 50 kW set one pump or compressor can be a third of the rating, and it pulls several times its running current to start. The motor that starts hardest usually decides the size, not the running total.
Rent for a season, buy for a site
A gap before the utility connects, a winter job or a trial on new gas: rent. A set that will sit on the same wellsite or remote shop for years usually costs less to own. The Offered column says which sets can be bought.
Where the gas comes from is covered in more depth on industrial natural gas generator rentals, and sites with no gas line on propane generators. Transformers, panels and cable are on power distribution rentals.
What each size puts down the cable.
The same set supplies more than twice the current at 208 V that it does at 480 V. That is why a small set feeding 120/208 V equipment needs heavier cable, or a transformer close to the load.
Figures are for a three-phase load at 0.8 power factor, rounded to the amp. The amperage table works any other rating, and the fuel consumption calculator gives a gas figure to take to the supplier.
| Rating | kVA | At 208 V | At 480 V | At 600 V |
|---|---|---|---|---|
| 25 kW | 31.25 | 87 A | 38 A | 30 A |
| 50 kW | 62.5 | 173 A | 75 A | 60 A |
| 70 kW | 87.5 | 243 A | 105 A | 84 A |
| 125 kW | 156.25 | 434 A | 188 A | 150 A |
| 135 kW | 168.75 | 468 A | 203 A | 162 A |
The listings, with photos.
A set shown here may still be booked on your dates; the desk confirms that on the quote. Each listing has the full specification.

KPS-30
25 kW- Output
- 30 kVA
- Frequency
- 60 Hz
- Voltage
- 120/208 V
- Fuel
- NG / LP

NG50
50 kW- Frequency
- 60 Hz
- Voltage
- 480 V
- Fuel
- NG / LP

Cummins 70 kW
70 kW- Frequency
- 60 Hz
- Voltage
- 480 V
- Fuel
- Natural Gas

NPI Series 125
125 kW- Output
- 156 kVA
- Frequency
- 60 Hz
- Voltage
- 480V
- Fuel
- NG / LP

CAT XQ135
135 kW- Frequency
- 60 Hz
- Voltage
- 480 V / 600 V
- Fuel
- Natural Gas
Where to go from here.
- Renting: the full gas range, small to large, is on natural gas generator rentals.
- Buying: new and NPI-built sets are on natural gas generators for sale, and used ones on used natural gas generators.
- One size in detail: the 70 kW natural gas generator page, then 100 kW, 150 kW and 200 kW as the load grows.
- Running it around the clock for months: read prime power natural gas generators first.

Questions about small gas generators.
What is the smallest natural gas generator you rent?
The KPS-30 · 25 kW Dual-Fuel Generator Set, rated 25 kW at 120/208 V.
Can a small natural gas generator run on propane?
Some can. KPS-30 · 25 kW Dual-Fuel Generator Set, NPI NG50 · 50 kW Natural Gas / Propane Generator and 125 kW Natural Gas Generator are listed for natural gas or propane. Running any set on a fuel its listing does not name is a question to settle on the quote, not on site.
Do you have a small gas generator at 120/208 V?
KPS-30 · 25 kW Dual-Fuel Generator Set is listed at a voltage that includes 208 V. The others are 480 V or 600 V, and feed a 120/208 V site through a step-down transformer, which can be rented with the set.
Will a small set run on gas from our lease?
That depends on the gas, so the first thing to send is a recent analysis and the pressure at the tie-in. 70 kW Cummins Natural Gas Generator is listed with a fuel-gas scrubber. Wet or sour gas changes what the set needs before it can burn it.
Can two small gas sets run in parallel?
Only sets built for it. XQ135 kW Portable Natural Gas Generator says so in its listing. Any other pairing is confirmed unit by unit before it is quoted.
What does a small natural gas generator cost to rent or buy?
There is no rate card. The quote is for the set you choose, whether you rent or buy, the term, transport from Red Deer, and any transformer, cable or gas train the site needs.
A small load on gas? Tell us three things.
The voltage, the biggest motor, and where the gas comes from. That is enough to say which set fits and send a written quote. Sets go out from Red Deer to sites across Alberta and Saskatchewan, with 24/7 field service behind them.