Skip to content
NPI — NexSource Power Inc.

Built, sold and serviced in Red Deer

Industrial generators.

Natural gas, propane and diesel generators for plants, leases, mines and facilities that need to own their power.

Buy an NPI Series set built in our own shop, pick a new-surplus or used unit from stock, or rent while you decide. Whichever you choose, the same Red Deer team services it afterwards.

An NPI Series 250 kW natural gas generator in the open bay door of the NexSource shop in Red Deer
An NPI Series 250 kW gas set at the shop door, finished and ready to leave.

Three ways to get one

Build it, buy it from stock, or rent it first.

01

Built new in Red Deer

The NPI Series is designed and assembled in the NexSource shop: 170, 250 and 350 kW natural gas and propane packages. When one needs service, the call goes to the people who built it.

The NPI Series
02

Bought from stock

New-surplus and used generators from other builders, gas and diesel, listed with their hours and condition where known. Ask for the overhaul record and how each unit was stored before you compare it with a new set.

Used generators for sale
03

Rented, then decided

When the term is uncertain, the load is still growing or the budget is not approved yet, renting keeps the site running while the purchase is worked out.

Industrial generator rental

Weighing ownership against a long rental? Renting vs. buying a generator sets out the costs on both sides, and leasing sits between the two.

Before you buy

Five decisions an owner lives with.

The kilowatt figure is the easy part. These are the choices that are hard to undo once the set is on its pad, and the ones worth settling before comparing quotes.

The fuel you will have for twenty winters

A rental can be fuelled however the job allows. An owned set is tied to the fuel on site for its working life: a utility gas line, gas from the lease, propane tanks or diesel storage. Choose the engine for the fuel the site will reliably have, not the fuel that is cheapest this year.

Voltage, settled before the order

Industrial services in Canada are mostly 600 V, and much of the generator market, the NPI Series included, is built at 480 V. Either the set is specified at the plant voltage or a transformer is part of the installation. Deciding that early avoids a surprise at hook-up.

Room to grow, or a second set later

A plant that expects to add load can buy a bigger set now or buy one that will parallel with a second later. Paralleling depends on the controller, so check that the listing says the unit is parallel-capable before counting on it.

How it will be housed

A weatherproof enclosure, an open skid inside a building, or a trailer if it may move between sites. The package affects noise, winter starting and how the set is serviced, and it is much harder to change after delivery.

Who will look after it

Parts for the engine and alternator, a technician who knows the controller, and load testing at intervals. Ask where service will come from before choosing between two otherwise similar sets.

Which rating to buy against, standby, prime or continuous, is explained on industrial generator rental. For the running and starting load, try the power calculators.

For sale now

Industrial generators on the sales list.

Every generator listed for sale, refreshed from the inventory each hour, smallest first. The condition comes from the listing; open a unit for its hours, specifications and photos.

Natural gas and propane

Including the NPI Series and dual-fuel sets.

UnitOutputVoltageConditionStatus
KPS-30 · 25 kW Dual-Fuel Generator Set25 kW120/208 VSee listingIn Stock
NPI NG50 · 50 kW Natural Gas / Propane Generator50 kW480 VSee listingIn Stock
70 kW Cummins Natural Gas Generator70 kW480 VSee listingIn Stock
125 kW Natural Gas Generator125 kW480VNew, built in Red DeerIn Stock
XQ135 kW Portable Natural Gas Generator135 kW480 V / 600 VUsed or new surplusIn Stock
MAN 155 kW Generator Package155 kW480 VSee listingIn Stock
NPI Series 170 · 170 kW Natural Gas / Propane Generator170 kW480 VNew, built in Red DeerIn Stock
200 kW · 600 V Natural Gas Generator200 kW347/600 VSee listingIn Stock
NPI250 · 14L · 250 kW Generator Set250 kW480 VNew, built in Red DeerIn Stock
NPI-350 · 350 kW Natural Gas / Propane Generator350 kW480 VNew, built in Red DeerIn Stock
Caterpillar 375 kW Natural Gas / Propane Generator375 kW600 V, 3 phaseSee listingIn Stock
Caterpillar XQ1250G Natural Gas Generator Set1,250 kW480 VUsed or new surplusIn Stock
Used XQ1475 kW Natural Gas Generator1,475 kW480 VUsed or new surplusIn Stock
1900 kW Natural Gas / Propane Generator1,900 kWOn requestSee listingIn Stock

Diesel

Self-contained, with fuel stored on site.

UnitOutputVoltageConditionStatus
60 kW Quiet Site Diesel Generator Set60 kWOn requestSee listingIn Stock
Used 150 kW Diesel Generator150 kW277/480 VUsed or new surplusIn Stock
Airman 320 kW Mobile Diesel Generator320 kW120/208 V · 277/480 V, 3 phaseSee listingIn Stock
500 kW Diesel Generator500 kW120–600VSee listingIn Stock

Browsing by fuel or condition instead? See natural gas generators, diesel generators, used natural gas generators or standby generators for sale. Engines on their own are on industrial natural gas engines.

The NPI Series

Our own industrial gas sets.

NexSource builds the NPI Series in Red Deer for the work Alberta asks of a gas generator: wellsite prime power, remote facilities and standby at plants. They come in three sizes, 170, 250 and 350 kW, and run on natural gas or propane at 480 V.

The 250 and 350 carry ComAp controllers that can parallel, so two or three of them can share a load that would otherwise need one much larger set, and one can be serviced while the others keep the site running.

See the NPI Series

170 kW

The smallest set, for a wellsite or a facility that would barely load a bigger one.

250 kW

The middle size, and the usual single-set answer for a producing site.

350 kW

The largest, and the one most often run in pairs or threes.

Where they go

From one shop to sites across two provinces.

NexSource has one location, on Queensgate Crescent in Red Deer. Generators sold there go to plants, leases and facilities across Alberta and into Saskatchewan, and transport is priced in the quote.

By city

Planning notes for Calgary and Edmonton facilities, and generator sales for Red Deer, Grande Prairie and Fort McMurray.

After the sale

Commissioning, planned maintenance and load bank testing come from the same shop, and the field service line, (403) 887-4567, is answered 24 hours a day. See generator service.

Industrial generator questions

Before you buy an industrial set.

What makes a generator industrial?

Mostly what it is asked to do. An industrial generator is built to run for long hours at a plant's voltage, start large motors and keep going in Alberta winters, with controls that report to the site. Size is part of it, but a 170 kW set on a wellsite is as industrial as a megawatt unit at a plant.

Do you build industrial generators?

Yes. The NPI Series, at 170, 250 and 350 kW on natural gas or propane, is designed and built by NexSource in Red Deer. Larger and diesel units on this page come from other manufacturers and are sold from stock.

Should we buy new or used?

New gives you a known build and no history to question. Used or new surplus can put a larger set on site for less, but the hours, the overhaul record and how it was stored matter more than the age. Ask for all three on any used unit, and compare it with renting if the need may be temporary.

Can an industrial generator run on gas from our lease?

Some can. It depends on the engine and the gas, so a current gas analysis is the starting point, along with pressure and how steady the supply is. Liquids are handled by an inlet scrubber and regulation sized for the set.

Do you supply industrial generators outside Alberta?

Saskatchewan is part of the service area. Everything is supplied from the Red Deer shop, and transport is quoted for the site. For anywhere else, call and describe the job.

Who installs and connects it?

A licensed electrician, either your own or one arranged as part of the package. The quote sets out the generator, any transformer, switching and cable, and who does each part of the connection.

What does an industrial generator cost?

There are no published prices. The set, its condition, the package, the voltage, any transformer or switchgear and transport all affect the price, and each is listed on the written quote.

Tell us the load, the fuel and the voltage.

With how long it will run each day and where it will sit, that is enough to compare a new NPI set, a unit from stock and a rental side by side.