Skip to content
NPI — NexSource Power Inc.

Gas, propane and diesel, rented from Red Deer

Industrial generator rental.

Generators for plants, leases, mines and project sites that run around the clock, start big motors and sit on 600 V.

Each set is picked for the rating it will really work at, configured for the plant's voltage and fuel, and load tested at the Red Deer shop before it leaves the yard.

Two containerised CAT natural gas generators, 1,900 kW each, on tri-axle trailers in the NexSource yard
The 1,900 kW gas units, the largest sets in the rental fleet.

What industrial duty asks

Four things that separate an industrial rental.

A contractor's portable and an industrial set can share a kilowatt figure. What they are asked to do is different, and these are the points where a rental gets sized wrong.

01

Rated for the hours it will run

A standby rating assumes a set runs only when the utility fails. Industrial rentals usually run every hour of the job, so the number that matters is the prime or continuous rating, which is lower. A set chosen off its standby figure can be undersized from the first day.

02

Sized for the biggest motor start

An induction motor started across the line draws six to eight times its running current for a few seconds. The generator has to hold its voltage through that, which often decides the size more than the running load does. Soft starters and drives cut the inrush and can bring the set down a size.

03

At the plant's voltage

Canadian industrial services are mostly 347/600 V. The fleet has sets built for 600 V and sets built for 480 V, and the voltage is on every listing. When the right size and the right voltage are not the same unit, a transformer goes in between.

04

With a plan for when it stops

Every engine needs oil changes and the odd repair. For loads that cannot go down, two smaller sets in parallel, or a spare beside the running one, let one be serviced while the other carries the site.

Voltage conversion is covered on transformer rentals, and the cable and panels between the set and the plant on power distribution rentals.

Reading the data plate

Standby, prime and continuous are three different numbers.

The same engine and alternator carry a different rating for each kind of duty. Ask which one a quoted figure is before comparing two sets.

Standby

Emergency use when the normal supply fails. The highest number on the data plate, for limited hours a year at a varying load.

Not for a rental that runs the site day after day.

Prime

Unlimited hours at a varying load, with the average held below the rating.

The usual basis for an industrial rental.

Continuous

Unlimited hours at a steady, near-constant load. The lowest of the three.

Base-load work such as a facility off the grid for months.

Running a site off the grid for weeks is prime duty; the prime power page covers how those rentals are planned.

On the rental list

The rental fleet by size.

Every generator listed for rent, read from the inventory every hour. The output shown is the listing's rating; the rating a set runs at on your job, and its derating for altitude and heat, are set in the quote.

Up to 100 kW

Pumps, small compressors, a lease or a control building.

UnitOutputFuelVoltage
KPS-30 · 25 kW Dual-Fuel Generator Set25 kWGas or propane120/208 V
NPI NG50 · 50 kW Natural Gas / Propane Generator50 kWGas or propane480 V
60 kW Quiet Site Diesel Generator Set60 kWDieselOn request
70 kW Cummins Natural Gas Generator70 kWNatural gas480 V

100 to 400 kW

Process skids, larger motor loads, a plant section during an outage.

UnitOutputFuelVoltage
125 kW Natural Gas Generator125 kWGas or propane480V
XQ135 kW Portable Natural Gas Generator135 kWNatural gas480 V / 600 V
Used 150 kW Diesel Generator150 kWDiesel277/480 V
NPI Series 170 · 170 kW Natural Gas / Propane Generator170 kWGas or propane480 V
175 kW Diesel Generator175 kWDiesel208/240/480V
200 kW Mobile Diesel Generator200 kWDieselOn request
200 kW · 600 V Natural Gas Generator200 kWNatural gas347/600 V
Cummins 230 kW Mobile Diesel Generator230 kWDiesel120/208 V · 277/480 V, 3 phase
NPI250 · 14L · 250 kW Generator Set250 kWGas or propane480 V
Airman 320 kW Mobile Diesel Generator320 kWDiesel120/208 V · 277/480 V, 3 phase
NPI-350 · 350 kW Natural Gas / Propane Generator350 kWGas or propane480 V
Caterpillar 375 kW Natural Gas / Propane Generator375 kWGas or propane600 V, 3 phase
400 kW Natural Gas Generator400 kWGas or propane208–600V, 3-Phase

Over 400 kW

Whole facilities, camps and staged loads, often with sets in parallel.

UnitOutputFuelVoltage
500 kW Diesel Generator500 kWDiesel120–600V
Caterpillar XQ1250G Natural Gas Generator Set1,250 kWNatural gas480 V
Used XQ1475 kW Natural Gas Generator1,475 kWNatural gas480 V
1900 kW Natural Gas / Propane Generator1,900 kWGas or propaneOn request

Comparing by fuel instead? See industrial natural gas rentals, diesel generator rentals or propane generators. Buying rather than renting? See natural gas and diesel generators for sale.

Where they work

Industrial rentals on the job.

Oil and gas production

Pump jacks, compressors and heat trace on leases ahead of a utility tie-in, often on gas from the lease itself.

Oilfield production

Mining

Contractor compounds, camps and equipment before permanent substations are energised, and cover during section shutdowns.

Mining

Plant turnarounds

Weeks of round-the-clock work with tie-ins for dozens of contractors across a laydown yard.

Turnaround power

Pipeline construction

Power that moves with the spread: welding, coating, pump stations and camps along the right-of-way.

Pipeline power

New facilities

Commissioning and early operation while the utility connection is still months away.

Gap power

Large loads

A megawatt and up, with sets run together and the distribution designed around them.

Megawatt power

How it is supplied

From the Red Deer shop to your site.

There is a single NexSource location: the Red Deer shop on Queensgate Crescent, where the NPI Series is built and every rental set is serviced and tested. Plants, leases and project sites across Alberta and into Saskatchewan are supplied from there, and the haul is priced in the written quote.

Prequalification

COR and ISNetworld are both held. Site-specific requirements from the operator are checked while the job is being quoted.

Service through the term

Oil changes and inspections are scheduled into the rental term. The field service line, (403) 887-4567, is open 24 hours a day, and when a technician can reach the site is settled on the call. See generator service.

Industrial rental questions

Before you rent an industrial set.

What sizes of industrial generator can I rent?

The rental list on this page reads from the live inventory and runs from small dual-fuel sets to multi-megawatt gas units. For loads beyond one set, two or more can run together. Send the load list and the quote names the units.

Should an industrial rental run on natural gas or diesel?

Where there is a gas line or usable lease gas, natural gas saves trucking fuel for the whole job, which matters on long rentals. Where there is none, diesel with an external tank is self-contained. Several gas sets also run on propane, which covers sites with no line at all.

Can the generator run on field gas from our lease?

Some packages can, depending on the engine and the gas. A current gas analysis decides it, together with the pressure at the tie-in and how steady the volume is. Liquids are knocked out by an inlet scrubber, which is specified along with the regulation.

Do you hold COR and ISNetworld?

Both are held. Operators often add their own prequalification steps on top, and those are worked through for each site as part of quoting.

Who connects the generator to our plant?

A licensed electrician: either the plant's own, or one brought in within the rental. The quote itemises the cable, panels, transformers and switching, and names who terminates them.

How long can an industrial rental run?

As long as the job needs, with servicing planned for the term. The written quote sets the term and the service schedule; for runs measured in seasons or years, a lease may suit better.

What does industrial generator rental cost?

There are no published rates. The total depends on the set, the rating it runs at, the term, the distribution and switching, fuel arrangements and the transport from Red Deer, and each is priced in the quote.

Send the load list and the largest motor.